Voltage/Current Specifications
LDS Model No: LDS50-40-115 AC |
| Description: The
LDS50-40-115 AC is a metal oxide varistor (MOV) over-voltage suppressor
designed for application on 115 VAC 400 Hz aerospace power systems. |
| Specifications: |
| Operating Temperature |
-55 to 80° |
| Storage Temperature |
-55 to 125° |
| Operating Voltage |
120 V (rms) |
| Maximum Continuous Operating
Voltage |
132 V (rms) |
| Maximum One-Second Over-Voltage |
400 V (rms) |
| Maximum Single Pulse Energy |
375 J (6 x 70
μs) |
|
|
| Clamp Voltage (typical): |
| @ 10 mA (peak) 400 Hz |
230 V (peak) |
| @ 1 kA (6 x 70
μs) (+) |
425 V (peak) |
| @ 5 kA (6 x 70
μs) (+) |
530 V (peak) |
| @ 10 kA (6 x 70
μs) (+) |
650 V (peak) |
|
| Maximum Single Pulse*
Currents |
| |
|
Cable Bundle
Test Level |
| WF 1 (6 x 70
μs) (+) |
10kA |
>>5 |
| WF 5A (40 x1 20
μs) (+) |
7 kA |
>>5 |
| WF 5B (50 x 500
μs) (+) |
1.8 kA |
>5 |
|
Maximum Multiple Stroke*
Currents
(14 Pulses in 2 s) |
| |
|
Cable Bundle
Test Level |
| WF 1 (6 x 70
μs) (+) |
6/3 kAš |
>5 |
| WF 5A (40 x1 20
μs) (+) |
4/2.16 kAš |
>5 |
| WF 5B (50 x 500
μs) (+) |
1000A/505Aš |
>4 |
|
*Waveforms in accordance
with SAE ARP5412 and RTCA/00-110D Section 22 Change Notice
šFirst
value is peak current of initial pulse, second is peak current of
subsequent pulses. |

|
Important Note: The protection effectiveness of the 115
VAC High Energy Surge Suppressor, or any other surge suppressor,
depends on many factors, including details of installation,
vulnerability levels of protected equipment and magnitudes of actual
transients, in addition to the suppressor characteristics. Therefore,
LDS can make no guarantee of protection effectiveness nor assume any
responsibility for loss or damage to protected equipment.
Click Here for PDF File
|