products.JPG (12805 bytes)

Low Voltage/High Energy Surge Suppressor Technical Data

text.gif (203 bytes)Back to Main Product Information
LDS50-60-28-X rev. K Specifications
LDS50-73-28-X rev. E
Specifications

Voltage/Current Specifications

LDS Model No: LDS50-60-28-1DC (offers clamping at 40 V)
(also available):  LDS50-73-28 (offers clamping at 50 V)

Description: The LDS50-60-28-1DC is a solid-state over-voltage suppressor designed for application on 28 volt dc, aerospace power systems.
Specifications:
Operating Temperature -55 to 80°
Storage Temperature -55 to 175°
Operating Voltage 28 V (dc)
Maximum Continuous Operating Voltage 36 V (dc)
Maximum One-Second Over-Voltage 40 V (dc)
Maximum Single Pulse Energy 90 J (40 x 120 μs)
Clamp Voltage (typical): @5 mA dc current               40.V (dc)

Current (A) Voltage (V) Energy (J)
1062 46.2 5.7
2168 48.2 12.9
2998 49.9 18.5
4000 51.1 25.6
4967 53 32.9
6083 55.6 41.8
6939 57.5 49.6
8068 58.6 58.9
9074 60.5 68.6
9992 63.6 79.6
10998 66 90.4
Maximum Single Pulse* Currents
   

Pin Test Level

WF 4 (6 x 70 μs) (+) 12kA >>5
WF 5A (40 x1 20 μs) (+) 11 kA >>5
WF 5B (50 x 500 μs) (+) 2 kA >5
Maximum Multiple Stroke* Currents
 (14 Pulses in 2 s)
   

Cable Bundle
Test Level

WF 1 (6 x 70 μs) (+) 9,000/4,500 A¹ >>5
WF 5A (40 x1 20 μs) (+) 7,500/3,750 A¹ >>5
WF 5B (50 x 500 μs) (+) 2,500/1,250 A¹ >5
*Waveforms in accordance with SAE ARP5412 and RTCA/D0-160D Section 22 Change Notice 3.
¹First value is peak current of initial pulse, second is peak current of subsequent pulses.



 


Important Note: The protection effectiveness of the Low Voltage/High Energy Surge Suppressor, or any other surge suppressor, depends on many factors, including details of installation, vulnerability levels of protected equipment and magnitudes of actual transients, in addition to the suppressor characteristics. Therefore, LDS can make no guarantee of protection effectiveness nor assume any responsibility for loss or damage to protected equipment.

Click Here for PDF File

Lightning Diversion Systems (LDS) lightning tests are always performed by Lightning Technologies, Inc. (LTI).


Home | About LDS | Products | Our Customers | Links | Press Releases | Contact Us