Voltage/Current Specifications
LDS Model No: LDS50-60-28-1DC (offers clamping at 40 V)
(also available):
LDS50-73-28 (offers clamping at 50 V) |
| Description: The
LDS50-60-28-1DC is a solid-state over-voltage suppressor designed for
application on 28 volt dc, aerospace power systems. |
| Specifications: |
| Operating Temperature |
-55 to 80° |
| Storage Temperature |
-55 to 175° |
| Operating Voltage |
28 V (dc) |
| Maximum Continuous Operating
Voltage |
36 V (dc) |
| Maximum One-Second Over-Voltage |
40 V (dc) |
| Maximum Single Pulse Energy |
90 J (40 x 120
μs) |
|
|
| Clamp Voltage (typical):
@5 mA dc current
40.V (dc)
 |
| Current (A) |
Voltage (V) |
Energy (J) |
| 1062 |
46.2 |
5.7 |
| 2168 |
48.2 |
12.9 |
| 2998 |
49.9 |
18.5 |
|
4000 |
51.1 |
25.6 |
|
4967 |
53 |
32.9 |
|
6083 |
55.6 |
41.8 |
|
6939 |
57.5 |
49.6 |
|
8068 |
58.6 |
58.9 |
|
9074 |
60.5 |
68.6 |
|
9992 |
63.6 |
79.6 |
|
10998 |
66 |
90.4 |
|
| Maximum Single Pulse*
Currents |
| |
|
Pin
Test Level |
| WF 4 (6 x 70
μs) (+) |
12kA |
>>5 |
| WF 5A (40 x1 20
μs) (+) |
11 kA |
>>5 |
| WF 5B (50 x 500
μs) (+) |
2 kA |
>5 |
|
Maximum Multiple Stroke*
Currents
(14 Pulses in 2 s) |
| |
|
Cable Bundle
Test Level |
| WF 1 (6 x 70
μs) (+) |
9,000/4,500 A¹ |
>>5 |
| WF 5A (40 x1 20
μs) (+) |
7,500/3,750 A¹ |
>>5 |
| WF 5B (50 x 500
μs) (+) |
2,500/1,250 A¹ |
>5 |
|
*Waveforms in accordance
with SAE ARP5412 and RTCA/D0-160D Section 22 Change Notice 3.
¹First
value is peak current of initial pulse, second is peak current of
subsequent pulses. |

|
Important Note: The protection effectiveness of the Low
Voltage/High Energy Surge Suppressor, or any other surge suppressor,
depends on many factors, including details of installation,
vulnerability levels of protected equipment and magnitudes of actual
transients, in addition to the suppressor characteristics. Therefore,
LDS can make no guarantee of protection effectiveness nor assume any
responsibility for loss or damage to protected equipment.